I/O Model Reference 157
Figure 58. Edgedivide Output and Timing
Table 58. Edgedivide Output Latency Values for Series 3100 Devices
Symbol Description Minimum Typical Maximum
t
fout
Function call to start of timer — 96 μs —
t
fod
Function to output disable — 82.2 μs —
t
sod
Active sync edge to output toggle 550 ns — 750 ns
t
win
Sync input pulse width (10 MHz) 200 ns — —